Description
Traction load cell in stainless steel ZAP
About this traction load cell in stainless steel : current-aligned signal for use with multiple load cells (reduces the setting time of the load cell chain).
Particularity of the traction load cell
- Traction load cell in stainless steel (5 ton and 7,5 ton)
- Protection rating IP68
- Max. number of LC intervals 3 000 OIML
- For traction weighing applications
Electrical data of the traction load cell ZAP:
- Supply voltage range: 15 Volts
- Rated output at Cn:
- ZAP 5 tonnes: 2 m V/V
- ZAP 5 tonnes: 2 m V/V
- Input impedance (resistance): 385 Ω ± 20 Ω
- Output impedance (resistance): 350 Ω ± 5 Ω
- Insulation resistance: 5 000 MΩ /50V
Metrological data of the traction sensor ZAP:
- Rated capacity (Cn): 5 tons, 7,5 tons
- Combined error: ± 0,017 % Cn
- Max supply tension: 15 Volts
- Compensated temperature range: -10 … +40 C°
- Temperature effect on sensitivity ≤ ± 0,0014 % Cn
- Creep error (30 min): 0,024 % range charge
- Maximum capacity (Emax): 5000kg, 7 500kg
- Max. number of LC intervals (n.max) (d OIML): 3 000
- Min. verification scale interval (Vmin): Emax/ 10 000 kg
- Z = Emax/ (2xDR): 3 000
Mechanical attribute for the tension load cell ZAP:
- Safe load limit 150 % range charge
- Protection rating IP68
- Material: Stainless steel
Example pratical apllication for the traction load cell ZAP :
- hanging conveyor belt
- hanging hopper
- mesuring traction effort
- modernization weighing scale